EHH-601DE Installation 1
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with these instructions will result in voiding of the product warranty and may result in personal injury
and/or property damage.
Maximum Wind-load: +/-150 PSF
Channel Installation
Flange/Sleeve Installation
Document 481315
EHH-601DE
Channel Installation
EHH-601DE Installation2
Maximum Size and Installation Information
Model ESD-635DE is a Miami-Dade Approved and Florida Product Approved louver and must be installed in accordance with the
installation instructions shown herein. Model ESD-635DE is qualified for installation within concrete/masonry, steel stud, structural
steel or wood framed building conditions. Model ESD-635DE is structurally calculated to withstand positive and negative wind-
loads up to +/-150 PSF. The maximum typical rough opening height is limited to 48.50 in. and the typical rough opening width is
limited to 48.75 in.
A
B
C
Minimum Typical Rough
Opening Size
12 in. W x 7 in. H
Maximum Typical
Rough Opening Size
48.75 in. W x 48.50 in. H
Maximum Wind-load: +/-150 PSF
Building Condition/Substrate Limitations
Channel Installation
All steel substrate should be min. 16 Ga. FY= 33 KSI
All concrete substrate shall be min. 2000 PSI
All concrete masonry shall be ASTM C90, Type II, grout-filled
All wood substrate shall be G= 0.42 density or better
All aluminum substrate shall be min 0.125 in. thick FY=16 KSI
Channel Installation
EHH-601DE Installation 3
Maximum Wind-load: +/-150 PSF
Channel Installation
EHH-601DE Installation4
Maximum Wind-load: +/-150 PSF
Channel Installation
EHH-601DE Installation 5
Maximum Wind-load: +/-150 PSF
Channel Installation
EHH-601DE Installation6
Maximum Wind-load: +/-150 PSF
Maximum Size and Installation Information
Model ESD-635DE is a Miami-Dade Approved and Florida Product Approved louver and must be installed in accordance with the
installation instructions shown herein. Model ESD-635DE is qualified for installation within concrete/masonry, steel stud, structural
steel or wood framed building conditions. Model ESD-635DE is structurally calculated to withstand positive and negative wind-loads
up to +/-150 PSF. The maximum typical rough opening height is limited to 48.50 in. and the typical rough opening width is limited to
48.5 in.
D
E
F
Minimum Typical Rough
Opening Size
12 in. W x 7 in. H
Maximum Typical
Rough Opening Size
48.50 in. W x 48.50 in. H
Building Condition/Substrate Limitations
Flange/Sleeve Installation
Any substrate acceptable that is capable of withstanding imposed loads.
Flange/Sleeve Installation
EHH-601DE Installation 7
Maximum Wind-load: +/-150 PSF
Flange/Sleeve Installation
4813 481315 • EHH-601DE Installation, Rev. 3, Jan. 2024 Copyright 2024 © Greenheck Fan Corporation
8
As a result of our commitment to continuous improvement, Greenheck reserves the right to
change specifications without notice.
Product warranties can be found online at Greenheck.com, either on the specific product page
or in the literature section of the website at Greenheck.com/Resources/Library/Literature.
Phone: 715.359.6171 • Fax: 715.355.2399 • Parts: 800.355.5354 • E-mail: [email protected] • Website: www.greenheck.com
Our Commitment
Maximum Wind-load: +/-150 PSF
Flange/Sleeve Installation